Product Overview
Condair 202 Steam Cylinder (151-9002)
The Condair 202 Steam Cylinder, part number 1519002, is a replaceable steam-generating cylinder for compatible Condair and Nortec electrode humidifiers. It is specified for selected EL, NHEL, RH2, RH Classic, MES, NHTC, NHPC, and NHMC humidifiers with 5–10 lb/hr output ratings operating at 120–277 VAC, single phase; the equipment model, electrical configuration, and existing cylinder number should be confirmed before ordering.
Part Details:
- Genuine Condair Type 202 replacement steam cylinder, manufacturer part number 1519002
- Designed for Condair electrode steam humidification equipment
- Manufacturer-listed compatibility includes EL, NHEL, RH2, RH Classic, MES, NHTC, NHPC, and NHMC series humidifiers
- Applicable to supported 5–10 lb/hr, 120–277 VAC, single-phase models
- Supplied with the 202 cylinder and an O-ring.
Documentation:
FAQs:
Q: Which humidifiers are compatible with the Condair 1519002 Cylinder 202?
A: The Condair 1519002 Cylinder 202 is manufacturer-listed for compatible EL, NHEL, RH2, RH Classic, MES, NHTC, NHPC, and NHMC series humidifiers rated for 5–10 lb/hr at 120–277 VAC, single phase. Verify the complete humidifier model, electrical rating, and existing cylinder number because not every configuration within these product families necessarily uses the same cylinder.
Q: How do I confirm that the Condair 202 cylinder is the correct replacement for my humidifier?
A: Confirm that the existing cylinder is marked 202, 1519002, or 151-9002, then compare the humidifier’s model, steam-capacity rating, voltage, and phase with Condair’s specifications. The equipment data plate and applicable Condair parts documentation should be used for final part selection.
Q: What does the Condair 202 steam cylinder do?
A: The Condair 202 serves as the replaceable steam-generation chamber in compatible electrode humidifiers. Electrical current passes through the water between the cylinder’s electrodes, generating heat that converts the water into steam.
Q: When should a Condair 1519002 steam cylinder be replaced?
A: Replace the cylinder when the humidifier indicates that it has reached the end of its service life or when inspection and manufacturer-prescribed maintenance identify replacement as necessary. Replacement timing can vary with operating conditions, water characteristics, equipment usage, and the specific humidifier model.
Q: Does water quality affect the service life of a Condair 202 cylinder?
A: Yes. Minerals left behind during steam production can accumulate in the cylinder, so water conditions can influence its operating life. The humidifier’s drain and control processes help manage mineral concentration, but actual service life can vary by installation.